ZX2
Sensore di spostamento laser, stabile, semplice e alla portata di tutti
Elevata precisione e stabilità delle misure, a un prezzo vantaggioso. Il nuovo sensore laser ZX2 garantisce prestazioni all'avanguardia in termini di precisione e velocità, per tutte le applicazioni di spostamento lineare. L'utilizzo di un sensore di immagini HSDR-CMOS garantisce elevata stabilità di misura, anche sulle superfici più complesse.
- Impostazione a sfioramento
- Precisione: 1,5–5 µm
- Per qualsiasi superficie
- Elevata velocità: 30 µs
Caratteristiche ed info per ordinare
Ordering information
Sensor heads
|
||||
|
||||
|
Amplifier units
Accessories (order separately)
These are not included with the sensor head or amplifier unit.
Calculating unit
Sensor head extension cables 1
Mounting brackets
Specifications
Diffuse reflective Sensor Heads
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 1 mW max. |
||||
Beam size1 |
||||
Resolution2 |
||||
Linearity3 |
||||
Temperature characteristic4 |
||||
Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) |
||||
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes. each in X,Y,and Z directions |
||||
300 m/s 2 3 times each in six directions (up/down,left/right,forward/backward) |
||||
Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Cable: PVC |
||||
Instruction sheet, Ferrite core, Laser warning label (English), FDA certification label |
Regular-reflective Sensor Heads
Visible-light semiconductor laser with a wavelength of 660 nm and an output of 0.24 mW max. EN class 1, FDA class I |
|
Beam size2 |
|
Resolution3 |
|
Linearity4 |
|
Temperature characteristic5 |
|
Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) |
|
10 to 150 Hz, 0.7-mm double amplitude, 80 minutes. each in X,Y,and Z directions |
|
300 m/s 2 3 times each in six directions (up/down,left/right,forward/backward) |
|
Case and cover: PBT (polybutylene terephtahalate), Optical window: Glass, Cable: PVC |
|
Instruction sheet, Ferrite core, Laser warning label (English) |
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
Amplifier units
Measurement period6 |
||
60 µs, 120 µs, 240 µs, 500 µs, 1 ms, 2 ms, 4 ms, 8 ms, 12 ms, 20 ms, 36 ms, 66 ms, 128 ms, 250 ms, 500 ms |
||
Analog output7 |
4 to 20 mA, Max. load resistance: 300Ω, ±5VDC or 1 to 5 VDC, Output impedance: 100Ω |
|
NPN open-collector outputs, 30 VDC, 50 mA max.(residual voltage: 1 V max. for load current 10 mA max.,2 V max. for load current above 10 mA) |
PNP open-collector outputs, 30 VDC, 50 mA max.(residual voltage: 1 V max. for load current 10 mA max., 2 V max. for load current above 10 mA) |
|
Laser OFF input, zero reset input, timing input, reset input, bank input |
ON: Short-circuited with 0-V terminal or 1.5 V or less |
ON: Supply voltage short-circuited or supply voltage within 1.5 V |
Smart tuning, scaling, sample hold, peak hold, bottom hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/clamp switch, (A-B)calculations8, thickness calculation3, mutual interference prevention3, laser deterioration detection, bank function (4 banks) |
||
Judgement indicators: HIGH (orange), PASS (green), LOW (orange), 11-segment main display (red), 11-segmentsub-display (orange), laser ON (green), zero reset (green), enable (green), menu (green), HIGH threshold (orange), LOW threshold (orange) |
||
3,000 mW max. with power supply voltage of 30 VDC and power supply current of 100 mA (with Sensor connected) |
||
Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) |
||
10 to 150 Hz, 0.7-mm double amplitude, 80 min. each in X,Y,and Z directions |
||
300 m/s 2 3 times each in six directions (up/down,left/right,forward/backward) |
||
Case: PBT(polybutylene terephtahalate), Cover: Polycarbonate, Display: Acrylic resin, Button: Polyacetal, Cable: PVC |
||
Calculating unit
2. Beam size: Defined as 1/e 2 (13.5%) of the central intensity at the smallest value of diameter for the measurement range (typical value) False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
3.
Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models: white ceramic object, regular-reflective models: 1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.)
Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
4. Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’ s standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50 (L): 20mm)
5. Temperature characteristic: Value for the case the space between the sensor head and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
*5 These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective models under EN 606825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has been completed for diffuse-reflective models and is scheduled for regular-reflective models.
2. Beam size: Defined as 1/e 2 (13.5%) of the central intensity at the smallest value of diameter for the measurement range (typical value) False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
3.
Resolution: indicates the degree of fluctuation (±3σ) of analog output when connected to the ZX2-LDA. (The measured value is given for the center distance for OMRON’s standard target object (diffuse-reflective models: white ceramic object, regular-reflective models: 1/4 λ flat mirror) when the response time of the ZX2-LDA is set to 128 ms.)
Indicates the repetition accuracy for when the workpiece is in a state of rest. Not an indication of distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field.
4. Linearity: indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’ s standard target object. Linearity and measured value may vary depending on target object. F.S. indicates the full scope of the measurement range. (ZX2-LD50 (L): 20mm)
5. Temperature characteristic: Value for the case the space between the sensor head and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
*5 These Sensors are classified as Class 2 laser devices for diffuse-reflective models and Class 1 for regular-reflective models under EN 606825-1 and the regulations of Laser Notice No. 50 for FDA certification. CDRH registration has been completed for diffuse-reflective models and is scheduled for regular-reflective models.
Come possiamo aiutarti?
Se hai domande o desideri richiedere un preventivo, contattaci o inviaci una richiesta.
Contattaci ZX2
ATTENZIONE! Non utilizzare questo modulo di contatto per i prodotti medicali Omron, per i quali vi invitiamo a consultare il sito Corman alla sezione Assistenza Tecnica.
Grazie per averci sottoposto la tua richiesta. Ti risponderemo non appena possibile.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadPreventivo per ZX2
Tramite questo modulo può richiedere un'offerta relativa al prodotto prescelto. Completi, per favore, i campi contrassegnati con *. I suoi dati personali verranno trattati secondo le normative vigenti. Le ricordo che il minimo importo fatturabile è di 400 € a cui bisogna aggiungere 25 € di spese amministrative.
Grazie per averci richiesto un'offerta. Vi risponderemo non appena possibile.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadCaratteristiche
Sensore di immagini HSDR CMOS
Il sensore ZX2 utilizza un sensore di immagini di nuova generazione High Speed & Dynamic Range (HSDR) CMOS. Esso garantisce misure stabili su superfici con elevato assorbimento e altamente riflettenti, senza perdita di precisione. Il sensore ZX2 monitora in continuo il livello di ricezione della luce e regola l'uscita del diodo laser per compensazione, il tutto in un tempo di ciclo di 60 μs.
Facilità di impostazione
ZX2 facile da impostare Il sensore ZX2 elimina le complesse procedure di impostazione dovute alla lunga regolazione dei parametri. Un pulsante intelligente consente di configurare il sensore per definire il tipo di superficie per la misura.
- Un tipo di superficie
- Più tipi di superfici
- Superfici altamente riflettenti
Applicazioni
Applicazione di rilevamento doppio foglio
La misura a elevata precisione e la possibilità di utilizzo con diversi tipi di superfici, consente al sensore ZX2 di essere impiegato per ispezioni a doppio foglio.
Applicazione per posizione di riferimento
È possibile effettuare misure lineari precise ad alta velocità, consentendo al sensore ZX2 di essere utilizzato per le applicazioni di riferimento della posizione ad alta velocità.
Applicazione di misura dello spessore
L'unità di calcolo del sensore ZX2 facilita la misura dello spessore. È possibile ottenere misure precise dello spessore anche su superfici estremamente riflettenti.
Misura della deformazione
Utilizzando più unità ZX2 è possibile esaminare la deformazione o la deviazione dei componenti. Anche se la temperatura o la superficie di misura varia, è comunque possibile ottenere misure stabili.