ZX-E
- Libreria CAD
- ZX-E Smart Sensors (Inductive Displacement Type) Catalogo tecnico
Thank you for downloading the ZX-E Smart Sensors (Inductive Displacement Type) Catalogo tecnico
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

Sensore di spostamento induttivo
Il sensore ZX-E offre la migliore soluzione in assoluto per la misura precisa degli oggetti metallici, particolarmente raccomandata in condizioni ambientali gravose come l'industria automobilistica e le macchine per la lavorazione dei metalli.
- Alta risoluzione: 1 µm
- Tempo di risposta ad alta velocità: 150 µs
- Testa di rilevamento facilmente sostituibile
- Concetto di piattaforma modulare per diverse tecnologie di rilevamento
- Linearità facilmente regolabile per qualsiasi metallo
Ordering information
Sensors
Sensor heads
Resolution1 |
||||
---|---|---|---|---|
ZX-ED01T2 |
||||
ZX-ED02T2 |
||||
ZX-EM02T2 |
||||
ZX-EM07MT2 |
||||
ZX-EM02HT4 |
Amplifier units
Note: Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Amplifier mounting brackets
SmartMonitor sensor setup tool for Personal Computer connection
ZX-SFW11EV35 |
|
Cables with connectors on both ends (for extension)*
* Robot cable models are also available. The model numbers are ZX-XC_R.
Specifications
Sensor heads
Magnetic metals |
||||||||
Resolution6 |
||||||||
Linearity7 |
±1% F.S.8 |
|||||||
Temperature characteristic9 |
||||||||
Operating10 |
||||||||
Storage5 |
||||||||
1,000 VAC, 50/60 Hz for 1 min between charged parts and case |
||||||||
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions |
||||||||
IEC60529, IP6011 |
||||||||
Amplifier units
Possible average count settings12 |
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 |
|
Linear output13 |
Current output: 4 to 20 mA/F.S., max. load resistance: 300 Ω Voltage output: ±4 V (±5 V, 1 to 5 V 14), output impedance: 100 Ω |
|
NPN open-collector outputs, 30 VDC, 50 mA max. |
PNP open-collector outputs, 30 VDC, 50 mA max. |
|
Zero reset input, timing input, reset input, judgement output hold input |
ON: Supply voltage short-circuited or supply voltage within 1.5 V |
|
|
||
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), |
||
0.5% F.S. of linear output value at ±20% of power supply voltage |
||
140 mA max. with power supply voltage of 24 VDC (with sensor connected) |
||
Operating and storage: 0 to 50°C (with no icing or condensation) |
||
10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions |
||
300 m/s2, 3 times each in 6 directions (up, down, left, right, forward, backward) |
||
Case: PBT (polybutylene terephthalate), cover: Polycarbonate |
||
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
Brochure
Mostra tutto brochureCataloghi
Manuali
Mostra tutto manualiIscrivetevi agli aggiornamenti di prodotti
Newsletter sulle ultime novità e innovazioni in termini di prodotti, soluzioni e servizi direttamente nella vostra casella di posta.
Grazie per la tua iscrizione! Riceverai a breve una E-mail di conferma con un link per attivare il servizio. Questo sistema di iscrizione è stato scelto per ottemperare alla legge sulla privacy e garantisce la riservatezza del tuo indirizzo E-mail.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadDocumentazione di prodotto
Scarica le schede tecniche, i manuali e le brochure.
Vai al Download CenterCorsi di formazione
Accedete ai corsi di formazione offerti dai nostri tecnici qualificati. Dal livello principiante ad avanzato.
Visualizzate i corsi di formazione