ZX-E
Sensore di spostamento induttivo
Il sensore ZX-E offre la migliore soluzione in assoluto per la misura precisa degli oggetti metallici, particolarmente raccomandata in condizioni ambientali gravose come l'industria automobilistica e le macchine per la lavorazione dei metalli.
- Alta risoluzione: 1 µm
- Tempo di risposta ad alta velocità: 150 µs
- Testa di rilevamento facilmente sostituibile
- Concetto di piattaforma modulare per diverse tecnologie di rilevamento
- Linearità facilmente regolabile per qualsiasi metallo
Caratteristiche ed info per ordinare
Ordering information
Sensors
Sensor heads
, | ||||
Amplifier units
Note: Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Amplifier mounting brackets
SmartMonitor sensor setup tool for Personal Computer connection
Cables with connectors on both ends (for extension)
*
undefined
* Robot cable models are also available. The model numbers are ZX-XC_R.
Specifications
Sensor heads
Magnetic metals |
||||||||
6
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.) The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields. |
||||||||
(including amplifier unit) |
||||||||
1,000 VAC, 50/60 Hz for 1 min between charged parts and case |
||||||||
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions |
||||||||
Amplifier units
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
2. Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.
Accuracy: The resolution is the deviation (
±3
σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9. Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.
The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
Come possiamo aiutarti?
Se hai domande o desideri richiedere un preventivo, contattaci o inviaci una richiesta.
Contattaci ZX-E
ATTENZIONE! Non utilizzare questo modulo di contatto per i prodotti medicali Omron, per i quali vi invitiamo a consultare il sito Corman alla sezione Assistenza Tecnica.

Grazie per averci sottoposto la tua richiesta. Ti risponderemo non appena possibile.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadPreventivo per ZX-E
Tramite questo modulo può richiedere un'offerta relativa al prodotto prescelto. Completi, per favore, i campi contrassegnati con *. I suoi dati personali verranno trattati secondo le normative vigenti. Le ricordo che il minimo importo fatturabile è di 400 € a cui bisogna aggiungere 25 € di spese amministrative.

Grazie per averci richiesto un'offerta. Vi risponderemo non appena possibile.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
Download