K6CM-ISM
- Libreria CAD
- K6CM Catalogo tecnico
Thank you for downloading the K6CM Catalogo tecnico
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

-
K6CM Motor Condition Monitoring Device
-
K6CM Motor Condition Monitoring Device
K6CM takes the burden of monitoring motors off maintenance engineers. Motors can be maintained in advance of failure due to deterioration. K6CM (comprehensive current diagnosis type) can consistently monitor motor conditions by observing the current waveform of the motor. Additionally, you can understand the motor's maintenance timing without depending on an engineer, because K6CM provides threshold value setting.
02:41 -
K6CM Demo Video
05:48
-
-
K6CM Demo Video
-
K6CM Motor Condition Monitoring Device
K6CM takes the burden of monitoring motors off maintenance engineers. Motors can be maintained in advance of failure due to deterioration. K6CM (comprehensive current diagnosis type) can consistently monitor motor conditions by observing the current waveform of the motor. Additionally, you can understand the motor's maintenance timing without depending on an engineer, because K6CM provides threshold value setting.
02:41 -
K6CM Demo Video
05:48
-
Dispositivi di monitoraggio dello stato dei motori
Quantificazione dello stato di un motore e di una pompa trifase a induzione. Come impostazione predefinita, la soglia di uscita dell'allarme è attiva. È possibile personalizzare il valore adattandolo alle esigenze dell'applicazione. Oltre a una diagnosi completa della corrente è possibile rilevare il degrado complessivo combinando ciascuna parte del motore con il rispettivo carico. La resistenza di isolamento del motore e della pompa trifase a induzione può essere misurata mediante il flusso di corrente (è inoltre possibile rilevare la corrente di dispersione sul lato secondario dell'inverter).
Poiché lo stato del motore può essere monitorato in valori numerici sul display a cristalli liquidi (LCD), è possibile controllarlo senza l'utilizzo di uno strumento dedicato.- Regolare le impostazioni di uscita dell'allarme a seconda del dispositivo, con riferimento al valore di soglia predefinito già impostato.
- In base al valore di soglia impostato per l'uscita dell'allarme, lo stato del motore può essere verificato visivamente tramite una barra, avente tre possibili colori; verde (normale), arancione (avvertenza) e rosso (critico).
- Dotato di un'uscita a transistor che trasmette all'esterno lo stato del motore e gli stati di errore dell'unità principale K6CM.
- Il monitoraggio può essere eseguito facilmente su un PC collegato via EtherNet/IP e tramite un software dedicato.
- Con lo stesso software dedicato è possibile monitorare i seguenti valori: vibrazioni, temperatura, resistenza di isolamento e corrente.
- L'andamento delle condizioni del motore può essere monitorato attraverso un software dedicato, per controllare le indicazioni di degrado.
- Sensore CT/ZCT a morsetto che facilita l'installazione in un sistema già esistente. Con un sensore CT/ZCT a morsetto, il dispositivo può essere installato senza dover sostituire o rimuovere il cablaggio nel contesto di un sistema già esistente.
- Fornito con funzione di auto-diagnosi del circuito interno dell'unità principale e del circuito di rilevamento analogico.
- La morsettiera con tecnologia Push-in Plus riduce il lavoro sul cablaggio (fori per l'inserimento di cavi doppi, per collegamenti elettrici incrociati).
- Certificazione UL (Listed) per agevolare la spedizione in Nord America (ZCT (IRT) con omologazione UL).
Ordering information
List of models
Input part
Vibration & temperature sensor (Order separately)
![]() |
![]() |
Note: The vibration and temperature sensor consists of a sensor head and a pre-amplifier.
A magnet is provided for the easy attachment of the vibration and temperature sensor.
ZCT (IRT) (Order separately)
Note: CT (IRT) is the abbreviation for Zero Current Transfer (Insulation Resistance Transfer).
A cable for connection is provided with the ZCT (IRT).
CT (Order separately)
Note: A cable for connection is provided with the CT. Select a CT that sets the current of the applicable motor within the measurement range.
EtherNet/IP communication cable recommended parts
Use a Category 5 or higher STP cable (shielded twisted pair cable).
NETSTAR-C5E SA 0.5 × 4P2 |
||
MPS588-C1 |
Industrial switching hub (recommended parts)
Priority control (QoS): EtherNet/IP control data priority |
|||||
Specifications
List of models
Ratings
Characteristics
Acceleration: Up to 9.99 G, |
||||
±35% rdg±2 digit (when the insulation resistance is 0.2 MΩ max.), when a 200-V/7.5-kW max. motor is used3 ±35% rdg±2 digit (when the insulation resistance is 0.4 MΩ max.), when a 400-V/7.5-kW max. motor is used1 |
||||
Contact configuration: NPN open collector (normal close) |
||||
Installation environment: Pollution degree 2, overvoltage category II, measurement category II |
||||
EN61326-1(EMI: Class A EMS: Industrial Location) Acceleration ± 0.1G, Velocity ±2.25mm/s, Temperature ± 6°C, insulation resistance ± 35% rdg, current ± 10% F.S. |
||||
Between all external terminals and the case Between all power supply terminals and all other terminals Between all sensor connection terminals and trigger input terminal + output terminal + all EtherNet/IP ports |
||||
Between all external terminals and the case Between all power supply terminals and all other terminals Between all sensor connection terminals and trigger input terminal + output terminal + all EtherNet/IP ports |
||||
Vibration frequency 10 to 55 Hz, slice amplitude 0.35 mm in each of X, Y, Z directions 5 minute × 10 |
||||
MS, NS 4 |
||||
Input part
Vibration & temperature sensor
Ratings
Characteristics
ZCT (IRT)
CT
Measurement range5 |
|||||||
Attachable wire diameter6 |
|||||||
Motor condition monitoring Tool (Software included with main unit)
37 |
||
1 hour, 1 day, 1 month, 3 months, 6 months, |
Brochure
Mostra tutto brochureFile descrittivi del dispositivo
Cataloghi
Mostra tutto cataloghiManuali
Mostra tutto manualiIscrivetevi agli aggiornamenti di prodotti
Newsletter sulle ultime novità e innovazioni in termini di prodotti, soluzioni e servizi direttamente nella vostra casella di posta.
Grazie per la tua iscrizione! Riceverai a breve una E-mail di conferma con un link per attivare il servizio. Questo sistema di iscrizione è stato scelto per ottemperare alla legge sulla privacy e garantisce la riservatezza del tuo indirizzo E-mail.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadDocumentazione di prodotto
Scarica le schede tecniche, i manuali e le brochure.
Vai al Download CenterCorsi di formazione
Accedete ai corsi di formazione offerti dai nostri tecnici qualificati. Dal livello principiante ad avanzato.
Visualizzate i corsi di formazione