Specifiche
| I/O system | NX I/O Bus |
| Type of module | Digital I/O |
| Number of digital inputs | 0 |
| Digital input type | None |
| Permitted voltage at input | 0-0 V |
| OFF/ON delay | 0.1-0.8 ms |
| Number of digital outputs | 32 |
| Digital output type | NPN |
| Permitted voltage at output | 15.0-28.8 V |
| Output current | 0.5 A |
| Short-circuit protected outputs | |
| Connection method | 1-wire |
| Signal processing | Free running, Standard speed, Synchronous |
| IO-Link master | |
| I/O connection type | FCN (plug not included) |
| Number of I/O connectors | 1 |
| Detachable I/O terminal block | |
| Suitable for safety functions | |
| SIL according to IEC 61508 | None |
| Communication port(s) | None |
| Number of IOV (V+) terminals | 4 |
| Number of IOG (V-) terminals | 4 |
| Number of COM terminals | 0 |
| Degree of protection (IP) | IP20 |
| Product Height (unpacked) | 100 mm |
| Product Width (unpacked) | 30 mm |
| Product Depth (unpacked) | 72.5 mm |
| Product Weight (unpacked) | 90 g |
Accessori
| G70A-ZOC16-3 DC24 | 16 uscite (interfaccia NPN verso PLC) |
|
|
| XW2D-20G6 | Morsettiera a 20 punti (M3) |
|
|
| XW2D-40G6 | Morsettiera a 40 punti (M3) |
|
|
| XW2K-40G-O32B CHN | Sistema di cablaggio di interfaccia PLC con tecnologia Push-in Plus e terminale di alimentazione, connettore MIL a 40 punti, ingresso/uscita, 0,5 A, NPN/PNP, 30 V CC, montaggio orizzontale e verticale su guida DIN |
|
|
| XW2K-40G-O32B-OUT CHN | Sistema di cablaggio di interfaccia PLC con tecnologia Push-in Plus e terminale di alimentazione, connettore MIL a 40 punti, uscita, segnale: 0,5 A, potenza: 7 A, NPN, 30 V CC, montaggio orizzontale e verticale su guida DIN |
|
|
| XW2Z-0100BF-L | Lunghezza 1 m connettore Fujitsu FCN40 lato I/O PLC e MIL40 lato morsettiera XW2D o XW2R |
|
|
| XW2Z-0100BH-L02 | lunghezza 1 m. connessione I/O PLC conn. Fujitsu FCN40 - 2x MIL20 per Morsettiere G70A-ZOC |
|
|
| XW2Z-0100BN-L | Cavo a fili liberi lunghezza 1 m. Connettore Fujitsu FCN 40 lato PLC |
|
|
| XW2Z-0200BF-L | Lunghezza 2 m connettore Fujitsu FCN40 lato I/O PLC e MIL40 lato morsettiera XW2D o XW2R |
|
|
| XW2Z-0200BH-L02 | Lunghezza 2 m. connessione I/O PLC conn. Fujitsu FCN40 - 2x MIL20 per Morsettiere G70A-ZOC |
|
|
| XW2Z-0200BN-L | Cavo a fili liberi lunghezza 2 m. Connettore Fujitsu FCN 40 lato PLC |
|
|
| XW2Z-0300BN-L | Cavo a fili liberi lunghezza 3 m. Connettore Fujitsu FCN 40 lato PLC |
|
|
| XW2Z-050B | Lunghezza 0,5 m per collegamento moduli di I/O con XW2B-40G4/G5 o XW2D |
|
|
| XW2Z-100B | Lunghezza 1 m per collegamento moduli di I/O con XW2B-40G4/G5 |
|
|
| XW2Z-150B | Lunghezza 1,5 m per collegamento moduli di I/O con XW2B-40G4/G5 e XW2D |
|
|
| XW2Z-200B | Lunghezza 2 m per collegamento moduli di I/O con XW2B-40G4/G5 |
|
|
| XW2Z-300B | Lunghezza 3 m per collegamento moduli di I/O con XW2B-40G4/G5 |
|
|
| XW2Z-RO100C-75 | Cavi per moduli PLC Omron Uscita: PLC Conn. Fujitsu 40; 2 Morsettiere G70V conn. MIL20 lungh. 1 m / 0,75 m |
|
|
| XW2Z-RO150C-125 | Cavi per moduli PLC Omron Uscita: PLC Conn. Fujitsu 40; 2 Morsettiere G70V conn. MIL20 lungh. 1,5 m / 1,25 m |
|
|
| XW2Z-RO200C-150 | Cavi per moduli PLC Omron Uscita: PLC Conn. Fujitsu 40; 2 Morsettiere G70V conn. MIL20 lungh. 2 m / 1,5 m |
|
|
| XW2Z-RO200C-175 | Cavi per moduli PLC Omron Uscita: PLC Conn. Fujitsu 40; 2 Morsettiere G70V conn. MIL20 lungh. 2 m / 1,75 m |
|
Area di download
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina
Effettua il login oppure registrati ai contenuti di questa pagina